Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Genes (Basel) ; 14(1)2023 Jan 16.
Article in English | MEDLINE | ID: covidwho-2199966

ABSTRACT

Background: Due to the extreme infectivity of SARS-CoV-2, sample-to-answer SARS-CoV-2 reverse transcription (RT) polymerase chain reaction (PCR) assays are urgently needed in order to facilitate infectious disease surveillance and control. The purpose of this study was to evaluate three sample-to-answer SARS-CoV-2 RT-PCR assays­BioFire COVID-19 Test, BioFire RP 2.1, and Cepheid Xpert Xpress SARS-CoV-2­using clinical samples. Methods: A total of 77 leftover nasopharyngeal swab (NP) swabs (36 positives and 41 negatives) confirmed by reference SARS-CoV-2 RT real-time (q) PCR assay were collected. The clinical sample concordance, as specified by their respective emergency use authorizations (EUAs), in comparison to the reference SARS-CoV-2 RT-qPCR assay, was assessed. Results: The results showed that all three sample-to-answer SARS-CoV-2 RT-PCR assays provided perfectly concordant results consistent with the reference SARS-CoV-2 RT-qPCR assay. The BioFire COVID-19 Test exhibited the best turnaround time (TAT) compared to the other assays, regardless of the test results, using one-way analysis of variance followed by Scheffe's post hoc test (p < 0.001). The Xpert Xpress SARS-CoV-2 showed a shorter average TAT (mean ± standard deviation, 49.9 ± 3.1 min) in the positive samples compared to that (55.7 ± 2.5 min) of the negative samples. Conclusions: Our evaluation demonstrates that the BioFire COVID-19 Test, BioFire RP 2.1, and Cepheid Xpert Xpress SARS-CoV-2 assays compare favorably to the reference SARS-CoV-2 RT-qPCR assay, along with a 100% concordance in assay results for clinical samples and an acceptable analytical performance at their guaranteed limits of detection. The addition of a widely used simultaneous sample-to-answer SARS-CoV-2 RT-PCR assay will contribute to the number of medical laboratories able to test for COVID-19.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Clinical Laboratory Techniques/methods , COVID-19 Testing , Nasopharynx , Sensitivity and Specificity
2.
Ann Lab Med ; 43(2): 137-144, 2023 03 01.
Article in English | MEDLINE | ID: covidwho-2089751

ABSTRACT

While the coronavirus disease 2019 pandemic is ongoing, monkeypox has been rapidly spreading in non-endemic countries since May 2022. Accurate and rapid laboratory tests are essential for identifying and controlling monkeypox. Korean Society for Laboratory Medicine and the Korea Disease Prevention and Control Agency have proposed guidelines for diagnosing monkeypox in clinical laboratories in Korea. These guidelines cover the type of tests, selection of specimens, collection of specimens, diagnostic methods, interpretation of test results, and biosafety. Molecular tests are recommended as confirmatory tests. Skin lesion specimens are recommended for testing in the symptomatic stage, and the collection of both blood and oropharyngeal swabs is recommended in the presymptomatic or prodromal stage.


Subject(s)
COVID-19 , Monkeypox , Humans , Monkeypox/diagnosis , COVID-19/diagnosis , Clinical Laboratory Techniques , Pandemics , Republic of Korea
4.
Talanta ; 252: 123835, 2023 Jan 15.
Article in English | MEDLINE | ID: covidwho-1984108

ABSTRACT

In this paper we present a new method for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), targeting a specific region "N gene." Under isothermal reaction conditions, we integrated ligation (Lig; high selectivity) and recombinase polymerase amplification (RPA; high sensitivity) processes, obtaining a robust method of detection. For point-of-care testing, we incorporated our laboratory-produced pyrophosphate ion (PPi)-sensing probe (PK-probe) for colorimetric analysis of the reaction. The total detection system was efficient and effective at diagnosing this RNA virus-mediated disease rapidly (30 min). In a full-genome SARS-CoV-2 study, our PK-probe/Lig-RPA system functioned with a limit of detection of 1160 copies/ml, with a single-mismatch level of selectively, and it was highly selective even in the presence of bacterial genomes commonly found in the human mouth and nose. This robust, straightforward, selective, efficient, and ultrasensitive colorimetric detection method, with potential for point-of-care analysis, should also be effective in detecting a diverse range of other RNA-based diseases.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , Recombinases , Colorimetry , Nucleic Acid Amplification Techniques/methods , COVID-19/diagnosis , Sensitivity and Specificity , RNA, Viral
5.
Ann Lab Med ; 42(4): 391-397, 2022 Jul 01.
Article in English | MEDLINE | ID: covidwho-1917192

ABSTRACT

Korean Society for Laboratory Medicine and the Korea Disease Prevention and Control Agency have announced guidelines for diagnosing coronavirus disease (COVID-19) in clinical laboratories in Korea. With the ongoing pandemic, we propose an update of the previous guidelines based on new scientific data. This update includes recommendations for tests that were not included in the previous guidelines, including the rapid molecular test, antigen test, antibody test, and self-collected specimens, and a revision of the previous recommendations. This update will aid clinical laboratories in performing laboratory tests for diagnosing COVID-19.


Subject(s)
COVID-19 , Clinical Laboratory Techniques , Humans , Pandemics , SARS-CoV-2 , Specimen Handling
6.
J Korean Med Sci ; 37(24): e192, 2022 Jun 20.
Article in English | MEDLINE | ID: covidwho-1902912

ABSTRACT

Croup is a common upper airway infection characterized by a barking cough, stridor, and hoarseness. It is usually caused by viral infection. A small number of croup caused by coronavirus disease 2019 (COVID-19) has been reported in children before the omicron variant surge. Previously reported cases indicated that croup caused by COVID-19 can be treated in the same manner as those with other viral causes. We describe two cases (9-month-old girl and 11-month-old boy) of previously healthy infants who presented with a barking cough and chest retraction and required endotracheal intubation and cardiopulmonary resuscitation. Despite receiving dexamethasone and nebulized racemic epinephrine (NRE) treatment for croup in the emergency department, these patients still developed acute respiratory failure. Reverse transcription polymerase chain reaction (RT-PCR) of nasopharyngeal samples revealed severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) omicron BA.2 variant (Stealth omicron) and no other common respiratory viral pathogens. Both patients were treated with mechanical ventilation, dexamethasone, and NRE in the pediatric intensive care unit. The duration of intubation was 112 hours and 80 hours, respectively. Both patients were discharged without complications. To the best of our knowledge, this is the first report of life-threatening croup produced by the omicron BA.2 variant and confirmed by RT-PCR. We suggest that this SARS-CoV-2 variant may cause severe croup that may not improve with conventional treatment, even in children without underlying diseases.


Subject(s)
COVID-19 Drug Treatment , Croup , Racepinephrine , Child , Cough , Croup/diagnosis , Croup/drug therapy , Dexamethasone/therapeutic use , Female , Humans , Infant , Male , SARS-CoV-2
7.
Anal Bioanal Chem ; 414(19): 5907-5915, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1899133

ABSTRACT

In this paper, we report a molecular diagnostic system-combining a colorimetric probe (RHthio-CuSO4) for pyrophosphate sensing and isothermal gene amplification (ramified rolling circle amplification)-that operates with high selectivity and sensitivity for clinical point-of-care diagnosis of SARS-CoV-2. During the polymerase phase of the DNA amplification process, pyrophosphate was released from the nucleotide triphosphate as a side product, which was then sensed by our RHthio-CuSO4 probe with a visible color change. This simple colorimetric diagnostic system allowed highly sensitive (1.13 copies/reaction) detection of clinical SARS-CoV-2 within 1 h, while also displaying high selectivity, as evidenced by its discrimination of two respiratory viral genomes (human rhino virus and respiratory syncytial virus) from that of SARS-CoV-2. All of the reactions in this system were performed at a single temperature, with positive identification being made by the naked eye, without requiring any instrumentation. The high sensitivity and selectivity, short detection time (1 h), simple treatment (one-pot reaction), isothermal amplification, and colorimetric detection together satisfy the requirements for clinical point-of-care detection of SARS-CoV-2. Therefore, we believe that this combination of a colorimetric probe and isothermal amplification will be useful for point-of-care testing to prevent the propagation of COVID-19.


Subject(s)
COVID-19 , COVID-19/diagnosis , Colorimetry , Diphosphates , Humans , Nucleic Acid Amplification Techniques , Point-of-Care Systems , Point-of-Care Testing , RNA, Viral , SARS-CoV-2/genetics , Sensitivity and Specificity
8.
Mikrochim Acta ; 189(5): 176, 2022 04 05.
Article in English | MEDLINE | ID: covidwho-1838341

ABSTRACT

A probing system has been developed based on dual-site ligation-assisted loop-mediated isothermal amplification (dLig-LAMP) for the selective colorimetric detection of SARS-CoV-2. This approach can induce false-positive and -negative detection in real clinical samples; dLig-LAMP operates with improved selectivity. Unlike RT-LAMP, the selectivity of dLig-LAMP is determined in both the ligation and primer binding steps, not in the reverse transcription step. With this selective system in hand, we developed a colorimetric signaling system for point-of-care detection. We also developed a colorimetric probe for sensing pyrophosphate, which arises as a side product during the LAMP DNA amplification. Thus, dLig-LAMP appears to be an alternative method for improving the selectivity problems associated with reverse transcription. In addition, combining dLig-LAMP with colorimetric pyrophosphate probing allows point-of-care detection of SARS-CoV-2 within 1 h with high selectivity.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Colorimetry/methods , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques/methods , Point-of-Care Systems , SARS-CoV-2/genetics
9.
Ann Lab Med ; 42(1): 96-99, 2022 Jan 01.
Article in English | MEDLINE | ID: covidwho-1350249

ABSTRACT

The sensitivity of molecular diagnostics could be affected by nucleotide variants in pathogen genes, and the sites affected by such variants should be monitored. We report a single-nucleotide variant (SNV) in the nucleocapsid (N) gene of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), i.e., G29179T, which impairs the diagnostic sensitivity of the Xpert Xpress SARS-CoV-2 assay (Cepheid, Sunnyvale, CA, USA). We observed significant differences between the threshold cycle (Ct) values for envelope (E) and N genes and confirmed the SNV as the cause of the differences using Sanger sequencing. This SNV, G29179T, is the most prevalent in Korea and is associated with the B.1.497 virus lineage, which is dominant in Korea. Clinical laboratories should be aware of the various SNVs in the SARS-CoV-2 genome and consider their potential effects on the diagnosis of coronavirus disease 2019.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Molecular Diagnostic Techniques , Nasopharynx , Nucleotides , Prevalence , Republic of Korea , Sensitivity and Specificity
10.
Ann Lab Med ; 42(1): 71-78, 2022 Jan 01.
Article in English | MEDLINE | ID: covidwho-1350248

ABSTRACT

BACKGROUND: Seroprevalence studies of coronavirus disease 2019 (COVID-19) cases, including asymptomatic and past infections, are important to estimate the scale of the disease outbreak and to establish quarantine measures. We evaluated the clinical performance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody assays available in Korea for use in seroprevalence studies. METHODS: The sensitivity, specificity, cross-reactivity, and interference of five SARS-CoV-2 antibody assays were evaluated using the following: 398 serum samples from confirmed COVID-19 patients, 510 negative control samples from before 2018 (pre-pandemic), 163 serum samples from patients with SARS, Middle East respiratory syndrome (MERS), and other viral infections, and five samples for the interference study. RESULTS: The sensitivities of the five assays ranged from 92.2% to 98%, and their specificities, including cross-reactivity and interference, ranged from 97.5% to 100%. The agreement rates were excellent (kappa >0.9). Adjustment of the cutoff values could be considered through ROC curve analysis. The positive predictive values of the individual assays varied from 3.5% to 100% at a 0.1% prevalence but were as high as ≥95% when two assays were combined. CONCLUSIONS: The prevalence of COVID-19 in Korea is considered to be exceptionally low at present; thus, we recommend using a combination of two or more SARS-CoV-2 antibody assays rather than a single assay. These results could help select SARS-CoV-2 antibody assays for COVID-19 seroprevalence studies in Korea.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Humans , Pandemics , Sensitivity and Specificity , Seroepidemiologic Studies
11.
Ann Lab Med ; 41(6): 588-592, 2021 Nov 01.
Article in English | MEDLINE | ID: covidwho-1264322

ABSTRACT

The rapid antigen test (RAT) for coronavirus disease (COVID-19) represents a potent diagnostic method in situations of limited molecular testing resources. However, considerable performance variance has been reported with the RAT. We evaluated the clinical performance of Standard Q COVID-19 RAT (SQ-RAT; SD Biosensor, Suwon, Korea), the first RAT approved by the Korean Ministry of Food and Drug Safety. In total, 680 nasopharyngeal swabs previously tested using real-time reverse-transcription PCR (rRT-PCR) were retested using SQ-RAT. The clinical sensitivity of SQ-RAT relative to that of rRT-PCR was 28.7% for all specimens and was 81.4% for specimens with RNA-dependent RNA polymerase gene (RdRp) threshold cycle (Ct) values ≤23.37, which is the limit of detection of SQ-RAT. The specificity was 100%. The clinical sensitivity of SQ-RAT for COVID-19 diagnosis was assessed based on the Ct distribution at diagnosis of 33,294 COVID-19 cases in Korea extracted from the laboratory surveillance system of Korean Society for Laboratory Medicine. The clinical sensitivity of SQ-RAT for COVID-19 diagnosis in the Korean population was 41.8%. Considering the molecular testing capacity in Korea, use of the RAT for COVID-19 diagnosis appears to be limited.


Subject(s)
COVID-19/diagnosis , RNA-Dependent RNA Polymerase/genetics , SARS-CoV-2/genetics , COVID-19/virology , COVID-19 Testing/methods , Humans , Nasopharynx/virology , RNA, Viral/analysis , RNA, Viral/metabolism , Real-Time Polymerase Chain Reaction , Republic of Korea , SARS-CoV-2/isolation & purification
12.
Anal Chim Acta ; 1158: 338390, 2021 May 08.
Article in English | MEDLINE | ID: covidwho-1141547

ABSTRACT

The development of rapid, highly sensitive, and selective methods for the diagnosis of infection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) should help to prevent the spread of this pandemic virus. In this study, we combined recombinase polymerase amplification (RPA), as a means of isothermal DNA amplification, with an rkDNA-graphene oxide (GO) probe system to allow the rapid detection of SARS-CoV-2 with high sensitivity and selectivity. We used in situ enzymatic synthesis to prepare an rkDNA probe that was complementary to an RPA-amplified sequence of the target N-gene of SARS-CoV-2. The fluorescence of this rkDNA was perfectly quenched in the presence of GO. When the quenched rkDNA-GO system was added to the RPA-amplified sequence of the target SARS-CoV-2, the fluorescence recovered dramatically. The combined RPA/rkDNA-GO system exhibited extremely high selectivity (discrimination factor: 17.2) and sensitivity (LOD = 6.0 aM) for the detection of SARS-CoV-2. The total processing time was only 1.6 h. This combined RPA/rkDNA-GO system appears to be a very efficient and simple method for the point-of-care detection of SARS-CoV-2.


Subject(s)
COVID-19/diagnosis , Graphite , Nucleic Acid Amplification Techniques , SARS-CoV-2/isolation & purification , Humans , Pandemics , Recombinases , Sensitivity and Specificity
14.
Clin Infect Dis ; 73(9): e3002-e3008, 2021 11 02.
Article in English | MEDLINE | ID: covidwho-939552

ABSTRACT

BACKGROUND: Positive results from real-time reverse-transcription polymerase chain reaction (rRT-PCR) in recovered patients raise concern that patients who recover from coronavirus disease 2019 (COVID-19) may be at risk of reinfection. Currently, however, evidence that supports reinfection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has not been reported. METHODS: We conducted whole-genome sequencing of the viral RNA from clinical specimens at the initial infection and at the positive retest from 6 patients who recovered from COVID-19 and retested positive for SARS-CoV-2 via rRT-PCR after recovery. A total of 13 viral RNAs from the patients' respiratory specimens were consecutively obtained, which enabled us to characterize the difference in viral genomes between initial infection and positive retest. RESULTS: At the time of the positive retest, we were able to acquire a complete genome sequence from patient 1, a 21-year-old previously healthy woman. In this patient, through the phylogenetic analysis, we confirmed that the viral RNA of positive retest was clustered into a subgroup distinct from that of the initial infection, suggesting that there was a reinfection of SARS-CoV-2 with a subtype that was different from that of the primary strain. The spike protein D614G substitution that defines the clade "G" emerged in reinfection, while mutations that characterize the clade "V" (ie, nsp6 L37F and ORF3a G251V) were present at initial infection. CONCLUSIONS: Reinfection with a genetically distinct SARS-CoV-2 strain may occur in an immunocompetent patient shortly after recovery from mild COVID-19. SARS-CoV-2 infection may not confer immunity against a different SARS-CoV-2 strain.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Female , Humans , Phylogeny , RNA, Viral/genetics , Reinfection , Young Adult
16.
Emerg Infect Dis ; 26(10): 2469-2472, 2020 10.
Article in English | MEDLINE | ID: covidwho-742705

ABSTRACT

To validate the specimen-pooling strategy for real-time reverse transcription PCR detection of severe acute respiratory syndrome coronavirus 2, we generated different pools including positive specimens, reflecting the distribution of cycle threshold values at initial diagnosis. Cumulative sensitivities of tested pool sizes suggest pooling of <6 specimens for surveillance by this method.


Subject(s)
Betacoronavirus/isolation & purification , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Mass Screening/methods , Pneumonia, Viral/diagnosis , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Humans , Nasopharynx/virology , Oropharynx/virology , Pandemics , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Sensitivity and Specificity
18.
Ann Lab Med ; 40(6): 439-447, 2020 11.
Article in English | MEDLINE | ID: covidwho-599917

ABSTRACT

Coronavirus disease 2019 (COVID-19) is a respiratory disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Early detection of COVID-19 and immediate isolation of infected patients from the naive population are important to prevent further pandemic spread of the infection. Real-time reverse transcription (RT)-PCR to detect SARS-CoV-2 RNA is currently the most reliable diagnostic method for confirming COVID-19 worldwide. Guidelines for clinical laboratories on the COVID-19 diagnosis have been recently published by Korean Society for Laboratory Medicine and the Korea Centers for Disease Control and Prevention. However, these formal guidelines do not address common practical laboratory issues related to COVID-19 real-time RT-PCR testing and their solutions. Therefore, this guideline is intended as a practical and technical supplement to the "Guidelines for Laboratory Diagnosis of COVID-19 in Korea".


Subject(s)
Betacoronavirus/genetics , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , COVID-19 , Coronavirus Infections/genetics , Coronavirus Infections/virology , Coronavirus Nucleocapsid Proteins , Guanidines/chemistry , Guidelines as Topic , Humans , Nasopharynx/virology , Nucleocapsid Proteins/genetics , Open Reading Frames/genetics , Oropharynx/virology , Pandemics , Phosphoproteins , Pneumonia, Viral/genetics , Pneumonia, Viral/virology , RNA, Viral/genetics , RNA, Viral/metabolism , Real-Time Polymerase Chain Reaction , Republic of Korea , SARS-CoV-2 , Thiocyanates/chemistry , Viral Envelope Proteins/genetics , Viroporin Proteins
SELECTION OF CITATIONS
SEARCH DETAIL